SRV-63 series AC servo drives Detailed parameter description
-132-
This parameter is used to select CAN communication baud rate. Available baud rate are as
follow:
Setting value
Baud rate
0
1000kbps
[1]
500kbps
2
250kbps
3
125kbps
4
50kbps
5
20kbps
P4.02
1
Data size
16bit
Data format
DEC
Modbus address
1804,1805
CANopen address
0x2402, 0x00
P4.03
1
485 communication baud
rate
Setting range
Default
Unit
Available mode
0~3
1
-
P
S
T
F
This parameter is used to select 485 communication baud rate. Available baud rate are as follow:
Setting value
Baud rate
0
9600bps
[1]
19200bps
2
38400bps
3
57600bps
P4.03
1
Data size
16bit
Data format
DEC
Modbus address
1806,1807
CANopen address
0x2403,0x00
P4.04
1
485 communication parity
mode
Setting range
Default
Unit
Available mode
0~5
0
-
P
S
T
F
This parameter is used to set the 485 communication parity mode and it only supports RTU mode.
Setting value
Baud rate
[0]
None (N, 8, 1)
1
Even (E, 8, 1)
2
Odd (O, 8, 1)
3
None(N, 8, 2)
4
Even(E, 8, 2)
5
Odd(O, 8, 2)
P4.04
1
Data size
16bit
Data format
DEC
Modbus address
1808,1809
CANopen address
0x2404,0x00
P4.05
1
CAN communication node
Setting range
Default
Unit
Available mode
1~127
1
-
P
S
T
F
This parameter is used to set the local (salve) CAN communication node no..
P4.05
1
Data size
16bit
Data format
DEC
Modbus address
1810,1811
CANopen address
0x2405,0x00