SRV-63 series AC servo drives Appendix
-247-
Chapter 10 Appendix
10.1 Setup parameter list
P
– position mode; S – speed mode; T – torque mode; F –fully-closed loop mode
The function codes with the superscript of “1” indicate that these parameters can be valid only when
the system is reset and restarted or repowered after disconnection.
The function codes with the superscript of “2” indicate that these parameters are valid when the servo
drive stops. The modification during operation is invalid.
The function codes with the superscript of “*” indicate that these parameters are not saved after
power off.
Function
code
Name
Unit
Range
Default
Available
Mode
P0 Basic control
P0.00
1
Motor model
-
0~9999999
2300
PSTF
P0.01
1
Encoder type
-
1~12
4
PSTF
P0.02
1
Forward rotation of motor
-
0~1
0
PSTF
P0.03
1
Control mode selection
-
0~9
0
PSTF
P0.04*
Internal enabling command
-
0~1
0
PSTF
P0.05
JOG speed
r/min
0~1000
200
PSTF
P0.06
1
Numerator of frequency division
output coefficient
-
0~(2
31
-1)
10000
PSTF
P0.07
1
Denominator of frequency
division output coefficient
-
1~(2
31
-1)
131072
PSTF
P0.08
1
Reverse of frequency division
output
-
0~1
0
PSTF
P0.09
Torque limit mode setting
-
0~6
1
PSF
P0.10
Max torque limit 1
%
0.0~500.0
300.0
PSTF
P0.11
Max torque limit 2
%
0.0~500.0
300.0
PSF
P0.13
1
Power of the external braking
resistor
W
0~5000
200
PSTF
P0.14
1
Resistance of the external
braking resistor
Ω
1~1000
60
PSTF
P0.15
Default monitoring parameters
-
0~22
0
PSTF
P0.16
Parameter modification
operation locked
-
0~1
0
PSTF
P0.17
EEPROM write mode
-
0~1
0
PSTF
P0.18*
Factory password
-
0~65535
0
PSTF
P0.20
1
Position command selection
-
0~4
0
PF