SRV-63 series AC servo drives Detailed parameter description
-103-
2. This function is only for read and cannot be set. The user can set the frequency of notch filter
according to the function code to remove the mechanical resonance.
3. 5000 indicates the resonance point is not found.
P1.21
Data size
16bit
Data format
DEC
Modbus address
1242,1243
CANopen address
0x2115, 0x00
P1.22
Data size
16bit
Data format
DEC
Modbus address
1244,1245
CANopen address
0x2116, 0x00
P1.23
1
st
notch filter frequency
Setting range
Default
Unit
Available mode
50~5000
5000
Hz
P
S
T
F
This parameter is used to set the frequency of 1
st
notch filter for suppressing resonance. The
notch filter can simulate the mechanical resonant frequency and thus suppressing the resonant
frequency.
When this parameter is set to 5000, the function of notch filter will be invalid.
P1.23
Data size
16bit
Data format
DEC
Modbus address
1246,1247
CANopen address
0x2117,0x00
P1.24
1
st
notch filter Q value
Setting range
Default
Unit
Available mode
0.50~16.00
1.00
-
P
S
T
F
This parameter is used to set the Q value (quality factor) of 1
st
notch filter
Q=Center frequency of 1
st
notch filter/bandwidth of the notch. Generally, this parameter should
remain in default value.
P1.24
Data size
16bit
Data format
DEC
Modbus address
1248,1249
CANopen address
0x2118,0x00
P1.25
1
st
notch filter depth
selection
Setting range
Default
Unit
Available mode
0~100
0
%
P
S
T
F
This parameter is used to set the amplitude attenuation rate of 1
st
notch filter.
When the setting value increases, the notch filter depth becomes shallow and phase lag will be smaller.
P1.25
Data size
16bit
Data format
DEC
Modbus address
1250,1251
CANopen address
0x2119,0x00
P1.26
2
nd
notch filter frequency
Setting range
Default
Unit
Available mode
50~5000
5000
Hz
P
S
T
F
P1.27
2
nd
notch filter Q value
Setting range
Default
Unit
Available mode
0.50~16.00
1.00
-
P
S
T
F
P1.28
2
nd
notch filter depth
selection
Setting range
Default
Unit
Available mode
0~100
0
%
P
S
T
F
Refer to P1.23, P1.24 and P1.25 for detailed parameters setting.
P1.26
Data size
16bit
Data format
DEC
Modbus address
1252,1253
CANopen address
0x211A,0x00