SRV-63 series AC servo drives Detailed parameter description
-199-
R0.48
Observing disturbance torque via
disturbance observer
Display range
Precision
Unit
-1000.0~1000.0
0.1
%
Compensation torque of disturbance observer
R0.48
Data size
32bit
Data format
DEC
Modbus address
4100,4101
CANopen address
0x3030,0x00
R0.49
Compensation value of
fully-closed-loop vibration suppressor
Display range
Precision
Unit
-9999.9~9999.9
0.1
r/min
Compensation value of fully-closed-loop vibration suppressor
R0.49
Data size
32bit
Data format
DEC
Modbus address
4102,4103
CANopen address
0x3031,0x00
R0.51
Observe load inertia ratio in real time
Display range
Precision
Unit
0~10000
1
%
Display load inertia ratio observed in real time.
R0.51
Data size
16bit
Data format
DEC
Modbus address
4106,4107
CANopen address
0x3033,0x00
R0.52
Linear encoder (2
nd
encoder) position
feedback accumulation (32-bit number)
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
pulse
Linear encoder (2
nd
encoder) position feedback accumulation, 32-bit number, fast reading speed.
If the data range exceeds 32-bit, use R0.57.
R0.52
Data size
32bit
Data format
DEC
Modbus address
4108,4109
CANopen address
0x3034,0x00
R0.53
Gantry synchronization position
deviation
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
reference unit
Gantry synchronization position deviation.
R0.53
Data size
32bit
Data format
DEC
Modbus address
4110,4111
CANopen address
0x3035,0x00
R0.54
Linear encoder
(2
nd
encoder)position
feedback value
Display range
Precision
Unit
0~2
23
1
pulse
Display the feedback position of
linear encoder
(2
nd
encoder).
R0.54
Data size
32bit
Data format
DEC
Modbus address
4112,4113
CANopen address
0x3036,0x00
R0.55
Encoder circle number offset after
clearing multi-turn position
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
-
Display the offset of encoder circles after zero clearing of multi-turn position.