SRV-63 series AC servo drives Detailed parameter description
-150-
P5.10
2
Data size
16bit
Data format
DEC
Modbus address
2020,2021
CANopen address
0x2505,0x00
P5.11
Homing automatically
after power on
Setting range
Default
Unit
Available mode
0~1
0
-
P
This parameter is used to set whether it can return to home automatically after power on.
Setting value
Instruction
[0]
Invalid
1
Valid
Note:
It is valid when no fault occurs.
P5.11
1
Data size
16bit
Data format
DEC
Modbus address
2022,2023
CANopen address
0x250B,0x00
P5.12
High speed of 1
st
step of
homing
Setting range
Default
Unit
Available mode
0~2000
100
r/min
P
This parameter is used to set the high speed of 1
st
step of homing.
Diagram:
P5.12
P5.13
Forward limit switch
Z
P5.12
P5.13
Forward limit switch
Z
P5.12
Data size
16bit
Data format
DEC
Modbus address
2024,2025
CANopen address
0x250C,0x00
P5.13
Low speed of 2
nd
step of
homing
Setting range
Default
Unit
Available mode
0~60
20
r/min
P
This parameter is used to set the low speed of 2
nd
step of homing. See details at P5.12.
P5.13
Data size
16bit
Data format
DEC
Modbus address
2026,2027
CANopen address
0x250D,0x00
P5.14
Home setting
Setting range
Default
Unit
Available mode
-(2
31
-1)~(2
31
-1)
0
reference unit P
This parameter is used to set the value of the home.
P5.14
Data size
32bit
Data format
DEC
Modbus address
2028,2029
CANopen address
0x250E,0x00
P5.15*
Trigger command of
homing
Setting range
Default
Unit
Available mode
0~1
0
-
P
This parameter is used to trigger the homing command. It has the same function with HOME
(0x017 or 0x117) of the digital output.