SRV-63 series AC servo drives Running and operation
-75-
5.2.5.4 Operation flowchart of program commissioning
Press
MODE
key to the auxiliary function mode. Press
UP/DOWN
key to the
menu, and
press
SET
key to the interface. The interface will display
. In the interface of
,
SHIFT
key can be used to switch between
and
, start and stop the
commissioning function. In the interface of
,
UP
/
DOWN
key can be used to start the
program commissioning and has no relationship with
P5.00. If the motor direction is counterclockwise,
it can be started by
UP
key. If the motor direction is clockwise, it can be started by
DOWN
key. After
starting, the interface will display the current speed.
SET
MODE
SHIFT
SHIFT
UP
DOWN
SHIFT
MODE
MODE
5.2.5.5 Operation flowchart of inertia identification
Press
MODE
key to the auxiliary function mode. Press
UP/DOWN
key to the
menu, and
press
SET
key to the interface. The interface will display
. Press
SET
key to start the inertia
identification. After finishing, the result
will be displayed for about 3 seconds and saved
automatically. It will return to eh parameters after displaying
for about 2 seconds.
SET
MODE
SET
MODE
Delay 3s
Delay 2s