SRV-63 series AC servo drives Detailed parameter description
-119-
Speed reaching
SR
0x10A
0x00A
S T
Speed limiting
SL
0x10B
0x00B
P S T
Speed command or not
SCMD
0x10C
0x00C
S
Speed zero output
ZSO
0x10D
0x00D
P S T
F
Torque limiting
LM
0x10E
0x00E
P S T
F
Zeroing finished
HEND
0x10F
0x00F
P
Torque reaching
TRCH
0x110
0x010
T
(Reserved)
/
0x111
0x011
(Reserved)
/
0x112
0x012
(Reserved)
/
0x113
0x013
(Reserved)
/
0x114
0x014
(Reserved)
/
0x115
0x015
PTP arrival
PTPF
0x116
0x016
P
PTP output 1
PTPO1
0x117
0x017
P
PTP output 2
PTPO2
0x118
0x018
P
PTP output 3
PTPO3
0x119
0x019
P
PTP output 4
PTPO4
0x11A
0x01A
P
PTP output 5
PTPO5
0x11B
0x01B
P
PTP output 6
PTPO6
0x11C
0x01C
P
PTP output 7
PTPO7
0x11D
0x01D
P
Gantry synchronization output clear
GSC
0x11E
0x01E
P
Dynamic braking relay control
DBRC
0x11F
0x01F
P S T
F
Note:
The default value is the function selection corresponds to position mode.
P3.10
1
Data size
16bit
Data format
HEX
Modbus address
1620,1621
CANopen address
0x230A, 0x00
P3.11
1
Output configuration of digital 2
Setting range
Default Unit Available mode
0x000~0x11F
0x003
-
P
S
T
F
P3.12
1
Output configuration of digital 3
Setting range
Default Unit Available mode
0x000~0x11F
0x007
-
P
S
T
F
P3.13
1
Output configuration of digital 4
Setting range
Default Unit Available mode
0x000~0x11F
0x00D
-
P
S
T
F
P3.14
1
Output configuration of digital 5
Setting range
Default Unit Available mode
0x000~0x11F
0x005
-
P
S
T
F
P3.15
1
Output configuration of digital 6
Setting range
Default Unit Available mode
0x000~0x11F
0x00E
-
P
S
T
F
These parameters are used to set the output function of digital value 2~6, and they are hex
numbers.
The setting method is the same as P3.10.
Note:
The default value is the function selection corresponds to position mode.
P3.11
1
Data size
16bit
Data format
HEX
Modbus address
1622, 1623
CANopen address
0x230B, 0x00