SRV-63 series AC servo drives Detailed parameter description
-104-
P1.27
Data size
16bit
Data format
DEC
Modbus address
1254,1255
CANopen address
0x211B,0x00
P1.28
Data size
16bit
Data format
DEC
Modbus address
1256,1257
CANopen address
0x211C,0x00
P1.29
3
rd
notch filter frequency
Setting range
Default
Unit
Available mode
50~5000
5000
Hz
P
S
T
F
P1.30
3
rd
notch filter Q value
Setting range
Default
Unit
Available mode
0.50~16.00
1.00
-
P
S
T
F
P1.31
3
rd
notch filter depth
selection
Setting range
Default
Unit
Available mode
0~100
0
%
P
S
T
F
Refer to P1.23, P1.24 and P1.25 for detailed parameters setting.
P1.29
Data size
16bit
Data format
DEC
Modbus address
1258,1259
CANopen address
0x211D,0x00
P1.30
Data size
16bit
Data format
DEC
Modbus address
1260,1261
CANopen address
0x211E,0x00
P1.31
Data size
16bit
Data format
DEC
Modbus address
1262,1263
CANopen address
0x211F,0x00
P1.32
4
th
notch filter frequency
Setting range
Default
Unit
Available mode
50~5000
5000
Hz
P
S
T
F
P1.33
4
th
notch filter Q value
Setting range
Default
Unit
Available mode
0.50~16.00
1.00
-
P
S
T
F
P1.34
4
th
notch filter depth
selection
Setting range
Default
Unit
Available mode
0~100
0
%
P
S
T
F
Refer to P1.23, P1.24 and P1.25 for detailed parameters setting.
P1.32
Data size
16bit
Data format
DEC
Modbus address
1264,1265
CANopen address
0x2120,0x00
P1.33
Data size
16bit
Data format
DEC
Modbus address
1266,1267
CANopen address
0x2121,0x00
P1.34
Data size
16bit
Data format
DEC
Modbus address
1268,1269
CANopen address
0x2122,0x00
P1.35
Vibration control mode of
position command
Setting range
Default
Unit
Available mode
0~2
0
-
P
F
This parameter is used to set the switching mode of the filter used for vibration control.
Setting value
Function
[0]
The 1
st
vibration control is valid
1
Switch between 1 and 2 according to VS-SEL
2
Automatic
Note:
When selecting by digital input terminals, it is necessary to configure one of P3.00~P3.09