SRV-63 series AC servo drives Detailed parameter description
-193-
R0.16
Output power
Display range
Precision
Unit
-500.0~500.0
0.1
%
Display the output mechanical power of the drive. If the rated power of servo motor is 100.0%, the
actual value will be converted to the percentage value to be displayed.
Note:
The negative value means the motor is in power generation state.
R0.16
Data size
16bit
Data format
DEC
Modbus address
4036,4037
CANopen address
0x3010,0x00
R0.17
Motor load ratio
Display range
Precision
Unit
0.0~500.0
0.1
%
Display the actual motor load ratio. If the rated power is 100.0%, the actual value will be converted
to the percentage value to be displayed.
R0.17
Data size
16bit
Data format
DEC
Modbus address
4038,4039
CANopen address
0x3011,0x00
R0.18
Molecule of actual electric gear
ratio
Display range
Precision
Unit
0~(2
31
-1)
1
-
Display the molecule coefficient of actual electric gear ratio
R0.18
Data size
32bit
Data format
DEC
Modbus address
4040,4041
CANopen address
0x3012,0x00
R0.19
Denominator of actual electric
gear ratio
Display range
Precision
Unit
1~(2
31
-1)
1
-
Display the denominator coefficient of actual electric gear ratio
R0.19
Data size
32bit
Data format
DEC
Modbus address
4042,4043
CANopen address
0x3013,0x00
R0.20
Position command speed
Display range
Precision
Unit
-9999.9~9999.9
0.1
r/min
Display the speed value corresponds to the position command.
R0.20
Data size
32bit
Data format
DEC
Modbus address
4044,4045
CANopen address
0x3014,0x00
R0.21
Motor speed (filtering)
Display range
Precision
Unit
-9999.9~9999.9
0.1
r/min
Display the speed of the servo motor after filtering process.
R0.21
Data size
32bit
Data format
DEC
Modbus address
4046,4047
CANopen address
0x3015,0x00