SRV-63 series AC servo drives Safety precautions
-II-
Safety precautions
Safety icons:
Following safety precautions should be paid attention to before any installation, configuration,
operation, maintenance and inspection:
Check whether the AC power supply is the same as the rated voltage of the servo drive, otherwise
fire, hurt, damage to the drive may occur.
Do not connect the input power cables to the output terminals, otherwise damage to the drive may
occur.
Do not carry out any insulation and voltage withstand test to the drive directly, and do not test the
control circuit of the drive by megameter.
Connect the drive and motor as correct phase sequence, otherwise drive fault or damage may
occur.
De-couple the motor load and run the motor independently before operation to avoid accidents.
Please ensure the drive can be disconnected from the power supply by E-switch before any
operation.
Set the corresponding parameters before operation, otherwise the drive may run abnormally or
beyond the expectation because of the load.
Only qualified electrical engineers can carry out the wiring, otherwise el ectric shock or fire may
occur.
Do not touch the conductive parts directly; do not connect any external cables (especially those
related to electricity) to the enclosure or short connect the external cables, otherwise electric
shock or short circuit may occur.
Rewire the drive after 15 minutes when disconnecting the power supply, otherwise electric shock
may occur.
Do ground with proper techniques because the touch current may be 0.5mA, otherwise electric
shock may occur.