SRV-63 series AC servo drives Faults and solutions
-236-
Chapter 9 Faults and solutions
9.1 Meanings of the fault alarm code and countermeasures
Code
Name
Causes
Countermeasures
Er01-0
IGBT fault
The actual output current
exceeds the specified value
1.Drive fault (drive circuit, IGBT
fault);
2.Short circuit of motor cable
U,V,W, or the motor cable is
grounded or connected
improperly;
3. Motor Burndown;
4. Reverse sequence of U, V, W
phase;
5. Parameters are inappropriate
and cause system divergence.
6. ACC/DEC of start/stop process
is too short;
7. Instantaneous load is too large.
1. Remove the motor cables and
enable the drive, if the fault persists,
replace the drive;
2.Check the motor cables and wiring
3.Reduce the value of P0.10 and
P0.11;
4.Comission the loop parameters to
stabilize the system and reduce the
value of P0.12;
5.Increase the ACC/DEC time;
6.Replace with the drive with larger
power;
7. Replace the motor.
Er02-0
Encoder fault
– The
encoder cable broken 1. The encoder is not connected;
2. The encoder connector
becomes loose;
3.One of U, V, W, A, B Z phase
cables is broken;
4. Reversed A/B phase of the
encoder;
5. Communication break or
abnormal data caused by noise;
6.Normal encoder communication
but abnormal communication
data;
7. FPGA communication overtime
8. The drive does not support the
encoder type.
1. Check the encoder connector or
replace the encoder cable if the
cable is disconnected;
2. Detect whether encoder power
voltage is normal;
3. Reduce the interference of the
encoder, route the encoder and
motor independently and connect
the shielded cables of the encoder to
FG;
4. If reporting encoder disconnection
fault when power on, check whether
the available drive encoder type is
consistent with the available motor
encoder type according to P0.01.
Er02-1
Encoder fault
–Encoder
feedback error is too
large
Er02-2
Encoder fault
– Parity
error
Er02-3
Encoder fault
–CRC
check error
Er02-4
Encoder fault
–Frame
error
Er02-5
Encoder fault
–Short
frame error
Er02-6
Encoder fault
– Encoder
overtime
Er02-7
Encoder fault
–FPGA
overtime
Er02-8
Encoder fault
–Low
voltage alarm of the
encoder
If multi-turn encoder is used, the
battery voltage of the external
encoder is between 3.0V~3.2V
1. Check the battery connection in
encoder cable;
2. Check whether the external