SRV-63 series AC servo drives Detailed parameter description
-106-
P2.01
1
st
speed integral time
constant
Setting range
Default
Unit
Available mode
0.1~1000.0
21.0
ms
P
S
T
F
This parameter is used to set the integral time constant of the speed loop. Decreasing the setting
value may improve the response, but it may easily cause vibration and noise. It should be noted
particularly that when this parameter is set to 1000, it means the integral action is invalid.
P2.01
Data size
16bit
Data format
DEC
Modbus address
1402,1403
CANopen address
0x2201, 0x00
P2.02
1
st
position gain
Setting range
Default
Unit
Available mode
0.0~3276.7
48.0
1/s
P
F
The responsiveness of servo system position loop is determined by the position gain. Increasing
the setting value may improve the position responsiveness and shorten the positioning time, but it
may easily cause vibration and noise.
P2.02
Data size
16bit
Data format
DEC
Modbus address
1404,1405
CANopen address
0x2202, 0x00
P2.03
1
st
speed detection filter
Setting range
Default
Unit
Available mode
100~5000
5000
Hz
P
S
T
F
This parameter is used to set 1
st
speed detection filter.
Note:
5000 means there is no filter. Setting this parameter to a small value may reduce motor
noise and speed fluctuation, but it also lower down the responsiveness.
P2.03
Data size
16bit
Data format
DEC
Modbus address
1406,1407
CANopen address
0x2203, 0x00
P2.04
1
st
torque filter
Setting range
Default
Unit
Available mode
0.00~25.00
0.84
ms
P
S
T
F
This parameter is used to set the time constant of torque filter.
P2.04
Data size
16bit
Data format
DEC
Modbus address
1408,1409
CANopen address
0x2204,0x00
P2.05
2
nd
speed gain
Setting range
Default
Unit
Available mode
0.0~3276.7
27.0
Hz
P
S
T
F
P2.06
2
nd
speed integral time
constant
Setting range
Default
Unit
Available mode
0.1~1000.0
1000.0
ms
P
S
T
F
P2.07
2
nd
position gain
Setting range
Default
Unit
Available mode
0.0~3276.7
57.0
1/s
P
F
P2.08
2
nd
speed detection filter
Setting range
Default
Unit
Available mode
100~5000
5000
Hz
P
S
T
F
P2.09
2
nd
torque filter
Setting range
Default
Unit
Available mode
0.00~25.00
0.84
ms
P
S
T
F