SRV-63 series AC servo drives Detailed parameter description
-136-
If P4.10 is 1, this parameter can be used to set the inertia ratio switching command.
Setting value
Function
Actual inertia ratio
[0]
Disabled
The first inertia ratio (P1.01)
1
Enabled
The second inertia ratio (P1.02)
P4.18*
Data size
16bit
Data format
DEC
Modbus address
1836,1837
CANopen address
0x2412,0x00
P4.19*
Zero speed clamp
command
Setting range
Default
Unit
Available mode
0~1
0
-
S
T
If P4.10 is 1, this parameter can be used to set the zero speed clamp command.
Setting value
Function
[0]
Disabled
1
Enabled
P4.19*
Data size
16bit
Data format
DEC
Modbus address
1838,1839
CANopen address
0x2413,0x00
P4.20*
Retention pulse clearing
Setting range
Default
Unit
Available mode
0~1
0
-
P
F
If P4.10 is 1, this parameter can be used to set the retention pulse clearing. The detailed mode is
determined by P3.45 and after clearing, R0.04 is 0.
Setting value
Function
[0]
Disabled
1
Enabled
P4.20*
Data size
16bit
Data format
DEC
Modbus address
1840,1841
CANopen address
0x2414,0x00
P4.21*
Torque limit switching
command
Setting range
Default
Unit
Available mode
0~1
0
-
P
S
T
F
If P4.10 is 1, this parameter can be used to set the torque limit switching control.
Setting value
Function
[0]
Disabled
1
Enabled
P4.21*
Data size
16bit
Data format
DEC
Modbus address
1842,1843
CANopen address
0x2415,0x00
P4.22*
External fault command
Setting range
Default
Unit
Available mode
0~1
0
-
P
S
T
F