SRV-63 series AC servo drives Running and operation
-72-
8. Setting of long parameters (corresponds to parameters with over 6 digits) in parameter area:
SHIFT
SHIFT
SHIFT
UP
DOWN
SET
UP
DOWN
MODE
SHIFT
UP
DOWN
SHIFT
SET
MODE
SHIFT
UP
DOWN
5.2.2 State monitoring mode
After power on, the screen will enter into “General monitoring mode”, display the parameters name for
about 2.5 seconds and then display the current value. After pressing
MODE
key,
UP/DOWN
key can
be used to switch monitoring parameters. See chapter 10.3
Common monitoring parameter table
for
details. The monitoring parameters displayed by default can be set via P0.15. If no operation is
carried out under interfaces other than parameter value display interface, it will return to the
monitoring parameter interface in 20 seconds.
Operation flowchart:
Delay 2.5s
or SET
UP
DOWN
DOWN
DOWN
UP
UP
MODE
MODE
MODE
Delay 2.5s
or SET
Delay 2.5s
or SET
5.2.3 Monitoring mode
MODE
key can be used to switch into the monitoring mode.
SHIFT
key can be used to select the
group number of the monitoring parameters,
UP/DOWN
can be used to select the internal parameter
number and pressing for a long time, it can be used to select the parameter number quickly. After
finding the target,
SET
key can be used to view the current value and
MODE
can be used to return