SRV-63 series AC servo drives Running and operation
-71-
Button function table:
Key
Function
MODE
Used to switch between different modes or return to previous menu
UP
Used to select parameter upwards or increase value
DOWN
Used to select parameter downwards or decrease value
SET/SHIFT
Press for a long time =SET
(about 0.6 seconds)
Used to select parameter downwards or decrease value
Press for a short time =SHIFT:
When setting a parameter, it is used to select the position of the current digit
Operation flowchart:
Fault mode
STO mode
Common
monitoring mode
Parameter
mode
Monitoring
mode
Auxiliary function
mode
MODE
MODE
MODE
MODE
MODE
MODE
PTP mode
MODE
If the drive is power on, the screen will display
for about 1 second, and then display
for about 1 second, after that, enter into the “General monitoring mode”.
1. Press
MODE
key to switch “General monitoring mode”→”Parameters mode”→”PTP mode”
→“ Auxiliary function mode”→“Fault mode”→“STO mode” as a cycle mode. If no fault or no STO
input, the fault mode and STO mode can be ignored.
2.
If new fault occurs, it will switch to “Fault mode” by pressing
MODE
key. If no key is pressed in 20
seconds, it will switch to “Fault mode” automatically.
3.
In “General monitoring mode”,
UP
/
DOWN
key can be used to switch monitoring parameters. The
name of parameters will display for 2.5 seconds, and then the current value will be displayed.
4. In parameters mode,
SHIFT
key can be used to switch the group number and
UP
/
DOWN
key can
be used to select the internal parameters number.
5. In the parameters setting mode, pressing
SHIFT
to make the flickering words move left and use
the
UP/DOWN
key to modify the setting value of the high bit.
6. After parameters setting, pressing
SET
key to save the parameters or execute the commands.
7. After parameters setting, the screen will display
(for storage parameter and when
P0.17 is set to 0 [individual storage]) or
(for non-storage parameter or P0.17 is set to 1
[batch storage]), and then return to the parameters mode automatically.