SRV-63 series AC servo drives Detailed parameter description
-117-
(Reserved)
/
0x126
0x026
(Reserved)
/
0x127
0x027
(Reserved)
/
0x128
0x028
(Reserved)
/
0x129
0x029
(Reserved)
/
0x12A
0x02A
Terminal JOG enabling
DJOG
0x12C
0x02C
P
Gantry synchronization input clear
GIN
0x12D
0x02D
P
Master gantry synchronization
alignment sensor
GSM
0x12E
0x02E
P
Slave gantry synchronization
alignment sensor
GSS
0x12F
0x02F
P
Dynamic braking relay feedback
DBS
0x130
0x030
P
S T F
Manual and automatic switching of
turret
DAT
0x131
0x031
P
Forward jogging of turret
DFJ
0x132
0x032
P
Reverse jogging of turret
DRJ
0x133
0x033
P
Note:
The default value is the function selection corresponding to the position mode.
P3.00
1
Data size
16bit
Data format
HEX
Modbus address
1600,1601
CANopen address
0x2300, 0x00
P3.01
1
Input configuration of digital 2
Setting range
Default
Unit Available mode
0x000~0x133
0x00D
-
P
S
T
F
P3.02
1
Input configuration of digital 3
Setting range
Default
Unit Available mode
0x000~0x133
0x004
-
P
S
T
F
P3.03
1
Input configuration of digital 4
Setting range
Default
Unit Available mode
0x000~0x133
0x016
-
P
S
T
F
P3.04
1
Input configuration of digital 5
Setting range
Default
Unit Available mode
0x000~0x133
0x019
-
P
S
T
F
P3.05
1
Input configuration of digital 6
Setting range
Default
Unit Available mode
0x000~0x133
0x01A
-
P
S
T
F
P3.06
1
Input configuration of digital 7
Setting range
Default
Unit Available mode
0x000~0x133
0x001
-
P
S
T
F
P3.07
1
Input configuration of digital 8
Setting range
Default
Unit Available mode
0x000~0x133
0x002
-
P
S
T
F
P3.08
1
Input configuration of digital 9
Setting range
Default
Unit Available mode
0x000~0x133
0x007
-
P
S
T
F
P3.09
1
Input configuration of digital 10
Setting range
Default
Unit Available mode
0x000~0x133
0x008
-
P
S
T
F
These parameters are used to set the input function of digital value 2~10, and they are hex
numbers.
The setting method is the same as P3.00.