SRV-63 series AC servo drives Detailed parameter description
-86-
This parameter is used to set the manner of pulse input.
There are 3 types of pulse input manners:
Setting
value
Pulse input
form
Signal form
Shown in the picture
CCW
CW
[0]
Pulse + mode Pulse+Sign
1
FWD/REV
pulse mode
CW+CCW
2
Quadrature
encoder
pulse mode
QEP
Remark: The pulse direction of the parameter can be reversed by P0.24
1
. Please refer to P0.24
1
for detailed information.
P0.23
1
Data size
16bit
Data format
DEC
Modbus address
1046,1047
CANopen address
0x2017, 0x00
P0.24
1
Reverse of pulse input
direction
Setting range
Default
Unit
Available mode
0~1
0
-
P
F
By setting this parameter, the direction of the input pulse can be reversed. At this time the actual
output speed direction of the servo drive is opposite to the direction indicated by the pulse input
form in P0.23.
Setting value
Pulse input
[0]
Pulse input direction does not change
1
Pulse input direction is opposite to the original input direction
P0.24
1
Data size
16bit
Data format
DEC
Modbus address
1048,1049
CANopen address
0x2018, 0x00
P0.25
Numerator of 1
st
electronic gear ratio
Setting range
Default
Unit
Available mode
0~(2
31
-1)
0
-
P
F
P0.26
2
Denominator of the
electronic gear ratio
Setting range
Default
Unit
Available mode
1~(2
31
-1)
10000
-
P
F
P0.27
Numerator of 2
nd
electronic gear ratio
Setting range
Default
Unit
Available mode
0~(2
31
-1)
0
-
P
F
P0.28
Numerator of 3
rd
electronic gear ratio
Setting range
Default
Unit
Available mode
0~(2
31
-1)
0
-
P
F
P0.29
Numerator of 4
th
electronic gear ratio
Setting range
Default
Unit
Available mode
0~(2
31
-1)
0
-
P
F