SRV-63 series AC servo drives Running and operation
-69-
5.1.9.4 Servo OFF sequence in running state
Dynamic brake state
PWM output
Electromagnetic
brake signal output
(BRK)
Servo ready output
(RDY)
Servo fault output
(ALM)
Servo enabling (SON)
Note 1: The switch on/off of the dynamic brake can be controlled by P4.30;
Note 2: The electromagnetic brake signal iS set by P3.57; if the speed is less than the setting value of
P3.58 during the time of P3.57, the BRK signal will become valid;
Note 3: The actual Electric level corresponding to input/output valid state Can be set by P3.00~P3.15.
No fault alarm
Servo has output
Motor brake
Motor brake-release
Servo has no output
Dynamic brake switches on
Note 1
Note 2
Enable
Disabled
Valid
Dynamic brake
switches off
Note 3
5.1.9.5 Sequence of fault alarm
Dynamic brake state
PWM output
Electromagnetic
brake signal output
(BRK)
Servo ready output
(RDY)
Servo fault output
(ALM)
Note 1: The switch on/off of the dynamic brake can be controlled by P4.30;
Note 2: The electromagnetic brake signal iS set by P3.57; if the speed is less than the setting value of
P3.58 during the time of P3.57, the BRK signal will become valid;
Note 3: The actual Electric level corresponding to input/output valid state Can be set by P3.00~P3.15.
Fault alarm
Servo has output
Motor brake
Motor brake-release
Servo has no output
Dynamic brake switches on
Note 1
Note 2
Dynamic brake
switches off
Normal
Valid
Invalid