SRV-63 series AC servo drives Detailed parameter description
-144-
communication (4012 corresponds to R0.04).
P4.83
Data size
16bit
Data format
DEC
Modbus address
1966,1967
CANopen address
0x2453,0x00
P4.84
Configuration of PZD
feedback parameter 2
Setting range
Default
Unit
Available mode
4000~5852
4018
-
P
S
T
F
This parameter is used to set the mapping content of feedback parameter 2 in PROFIBUS-DP
communication (4018 corresponds to R0.07).
P4.84
Data size
16bit
Data format
DEC
Modbus address
1968,1969
CANopen address
0x2454,0x00
P4.85
Configuration of PZD
feedback parameter 3
Setting range
Default
Unit
Available mode
4000~5852
4032
-
P
S
T
F
This parameter is used to set the mapping content of feedback parameter 3 in PROFIBUS-DP
communication (4032 corresponds to R0.14).
P4.85
Data size
16bit
Data format
DEC
Modbus address
1970,1971
CANopen address
0x2455,0x00
P4.86
PPO type of DP
communication
Setting range
Default
Unit
Available mode
5
5
-
P
S
T
F
This parameter is used to set the frame type of PROFIBUS-DP communication.
0
1
2
3
4
5
6
7
8
9
10
11
CW
SW
Down
Up
SPD_REF POS_REF TRQ_REF
SPD_FBK POS_FBK TRQ_FBK
RSV
RSV
PZD1
PZD2
PZD3
PZD1
PZD2
PZD3
ID
ID
IND
VALUE
IND
VALUE
Parameter
Idendification
PKW
Fixed area
Freely mappable area
Process Data
Type5
Note:
SRV-63 only supports PROFIBUS-DPV0 and the PPO only supports 5.
P4.86
Data size
16bit
Data format
DEC
Modbus address
1972,1973
CANopen address
0x2456,0x00
P4.87
CANopen communication
cycle
Setting range
Default
Unit
Available mode
0~(2
31
-1)
0
us
P
S
T
F
CANopen communication cycle of the slave station.
Note:
The recommended unit for setting is 1000us.
P4.87
Data size
32bit
Data format
DEC
Modbus address
1974,1975
CANopen address
0x2457,0x00