SRV-63 series AC servo drives Detailed parameter description
-191-
R0.03
Command pulse accumulation
Display range
Precision
Unit
-(2
63
-1)~(2
63
-1)
1
reference unit
Accumulate and display the command pulse accumulation. With sign and the unit is the user unit.
R0.03
Data size
64bit
Data format
DEC
Modbus address
4008,4009,
4010,4011
CANopen address
0x3003,0x00
0x3003,0x01
R0.04
Retention pulse
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
reference unit
Display the number of retention pulses of the position deviation counter. The unit is the user unit.
R0.04
Data size
32bit
Data format
DEC
Modbus address
4012,4013
CANopen address
0x3004,0x00
R0.05
Hybrid control deviation
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
reference unit
This parameter is used to display the tolerance between the encoder feedback position and the
grating feedback position in fully-closed up mode. With sign, and the unit is the user unit.
R0.05
Data size
32bit
Data format
DEC
Modbus address
4014,4015
CANopen address
0x3005,0x00
R0.06
Current torque
Display range
Precision
Unit
-500.0~500.0
0.1
%
Display the actual torque at present. If the rated torque of servo motor is 100.0%, the actual value
will be converted to percentage value to be displayed.
R0.06
Data size
16bit
Data format
DEC
Modbus address
4016,4017
CANopen address
0x3006,0x00
R0.07
DC voltage of main circuit
Display range
Precision
Unit
0.0~1000.0
0.1
V
Display the DC voltage of main circuit.
R0.07
Data size
16bit
Data format
DEC
Modbus address
4018,4019
CANopen address
0x3007,0x00
R0.08
Voltage of control power
Display range
Precision
Unit
0.0~1000.0
0.1
V
Display the DC voltage of control power.
R0.08
Data size
16bit
Data format
DEC
Modbus address
4020,4021
CANopen address
0x3008,0x00
R0.09
Output voltage
Display range
Precision
Unit
0.0~1000.0
0.1
Vrms
Display the valid value of the current output voltage.