SRV-63 series AC servo drives Detailed parameter description
-203-
R1.15
Analog compensation
torque
Display range
Precision
Unit
-1000.0~1000.0
0.1
%
Display analog compensation torque
R1.15
Data size
32bit
Data format
DEC
Modbus address
4230,4231
CANopen address
0x310F,0x00
R1.16
DI capture encoder value
Display range
Precision
Unit
-(2
31
-1)~(2
31
-1)
1
pulse
Display the encoder value captured by DI input.
R1.16
Data size
32bit
Data format
DEC
Modbus address
4232,4233
CANopen address
0x3110,0x00
6.9.3 Fault record parameter (R3)
R3.00
Fault code record
Display range
Precision
Unit
-
-
-
Display the fault code when fault occurs.
The default is the latest 1 fault record.
R3.01
Power on time when fault
occurs
Display range
Precision
Unit
0~(2
31
-1)
1
s
Display the power on time when fault occurs.
R3.02
Operation time when fault
occurs
Display range
Precision
Unit
0~(2
31
-1)
1
s
Display the operation time when fault occurs.
R3.03
Motor speed when fault occurs
Display range
Precision
Unit
-20000~20000
1
r/min
Display the motor speed when fault occurs.
R3.04
Speed command when fault
occurs
Display range
Precision
Unit
-20000~20000
1
r/min
Display the speed command when fault occurs.
R3.05
Feedback pulse accumulation
when fault occurs
Display range
Precision
Unit
-(2
63
-1)~(2
63
-1)
1
reference unit
Display the feedback pulse accumulation when fault occurs.
R3.06
Command pulse accumulation
when fault occurs
Display range
Precision
Unit
-(2
63
-1)~(2
63
-1)
1
reference unit
Display the command pulse accumulation when fault occurs.