Figure 26-5 MII clock sources (provided b y CLKOUT pin)
25MHz
AT32F407
HEXT/PLL
E
M
A
C
TX_CLK
RX_CLK
25MHz
CLKOUT
PHY
Figure 26-6 MII clock sources (provided b y an external oscillator)
AT32F407
E
M
A
C
TX_CLK
RX_CLK
PHY
25MHZ OSC
RMII clock sources
As shown in Figure 26-7, both the EMAC and PHY require 50MHz clock sources, which can be done
with an external crystal oscillator or CLKOUT pin. When the CLKOUT pin is used, the PLL has to be
configured to generate this clock. Refer to CRM section for more information.