e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 196
[CE41] Image quality TRC control test pattern abnormality
Classification
Error item
Image control related service call
The image quality TRC control test pattern is not printed
normally.
Step
Check item
Result
Measures
Next
step
1
Change the setting of the
image quality TRC control to
"Disabled". Set the values of
08-2600 and 08-8103 to "0".
2
2
Output several number of
sheets of the image quality
control test pattern (04-270)
and the list print
([9][START]->101), and
check the pattern of each
color. Is the image normal?
YES
3
NO
•
Check if process units and developer units
are properly installed.
•
Check if there is any scattered toner or
developer material around the LED head,
clean it if there is any.
•
Correct the problem by referring to
"Troubleshooting for the Image".
P. 8-277 "8.5 Troubleshooting for the
3
Change the setting of the
image quality TRC control to
"Enabled". Set the values of
08-2600 and 08-8103 to "1".
4
4
Perform the automatic
gamma adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 5.
5
4.Check if the harness
between the connector
CN128 on the SYS board
and the connector CN350 on
the LGC board is
disconnected or open
circuited. Correct if so.
6
6
6.Check if the conductor
patterns on the SYS board
and the LGC board are short
circuited or open circuited.
7
7
7.If no abnormality is found
in steps 5 to 6 above,
replace the IMG board.
8
8
8.Perform automatic gamma
adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 9.
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...