8
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
8 - 209
[C3E1] Drum/cleaner/charger unit replacement (old-new) detection abnormality
Harness
Classification
Contents
Copy process related service call
Drum/cleaner/charger unit replacement (old-new) detection
abnormality
Step
Check Item
Result
Measure
Next
Step
1
Check if the old/new detection bar
of the drum cleaner unit is being
ejected.
Yes
4
No
2
2
Check if the harness of the drum
old/new detection switch in the
drum cleaner unit is open circuited.
Yes
3
No
Replace the harness.
3
Is the drum old/new detection
switch of the drum cleaner unit
normal?
Yes
4
No
Replace the drum old/new detection
switch.
4
Check if the drum old/new
detection pusher is moved to the
escape position while the coupling
of the drum cleaner unit is rotated
by hand.
(Is a driving in the old/new
detection pusher section
transmitted?)
Yes
3
No
Correct the drum old/new detection
pusher so that it is moved to the
escape position.
5
Check that the coupling of the
drum TBU drive unit is driven
properly.
Yes
Correct the engagement of the
couplings in the drum TBU drive unit
and the drum cleaner unit.
9
No
6
6
Check that the drum TBU drive
motor rotates properly. (Input
check: 03-112)
Yes
9
No
7
7
Check that the connector of the
drum TBU drive motor is
connected properly.
Yes
9
No
8
8
Check if the harness of the drum
TBU drive motor is open circuited.
Yes
9
No
Replace the drum TBU drive motor.
9
Check that the connector of the
LGC board (CN360) is connected
properly.
Yes
11
No
Reconnect the connector.
10
Is the harness of the LGC board
normal?
Yes
11
No
Replace the harness.
11
Is the LGC board normal?
Replace the LGC board.
Replacement part
Measure
Drum old/new detection switches
Drum TBU motor
LGC board
Replacement part
Measure
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...