05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
System
Network
IP Filtering
8804
Enable/Disable setting
2
1-2
SYS 1: Enabled 2: Disabled
1
08
Setting
mode
System
Network
MAC Address
Filtering
8805
Enable/Disable setting
2
1-2
SYS 1: Enabled 2: Disabled
1
08
Setting
mode
System
Network
IPsec
NAT-Traversal
8820
Enable/Disable setting
1
1-3
NIC 1: Default (IKEv1: Disabled, IKEv2: Enabled)
2: Enable IKEv1 & IKEv2
3: Disable IKEv1 & IKEv2
12
08
Setting
mode
System
Network
IPsec
CRL
8821
Enable/Disable setting
2
1-2
NIC 1: Enable CRL
2: Disable CRL
12
08
Setting
mode
System
Network
8824
FTP client mode
0
0-2
NIC Sets the FTP transfer mode when FTP is selected for
"FILE" to save the scanned data.
0: Automatic
1: Passive mode
2: Active mode
12
08
Setting
mode
System
Network
8825
Sending of host
announcement in
Super Sleep mode
1
1-2
NIC Since MFP is deleted from the master browser of
Windows network if MFP is in the Super Sleep mode for
36 minutes or more, enable this setting to always
display MFP in the browse list.
1: Enabled
2: Disabled
12
08
Setting
mode
System
Network
Dynamic update of
DNS server
8826
Enable/Disable setting
1
1-2
NIC Sets whether the function that gets the secondary DNS
server to work as the primary DNS server temporarily is
enabled or not when the primary DNS server is not
available.
1: Enabled 2: Disabled
12
08
Setting
mode
System
Network
Dynamic update of
DNS server
8827
Operating interval
60
1-1440
NIC Sets the operating interval of dynamic update.
1-1440 (min.)
12
08
Setting
mode
System
Network
8831
Time-out period for
EWB network
connection
60
1-300
SYS 1 to 300 (sec.)
1
08
Setting
mode
System
General
Registration number
for workflow
8900
0
Total
2000
1000-2000
SYS Changes the maximum number for workflow that is
registrable.
4
08
Setting
mode
System
General
Registration number
for workflow
8900
1
Number of interrupt
copy
1
1
SYS Changes the maximum number for workflow that is
registrable.
4
212
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...