05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Printer
LED
4722
Switchover of I/F
initialization
abnormality check
between LED and
LGC (CE81)
0
0-1
M
0: Enabled 1: Disabled
1
08
Setting
mode
Printer
LED
4723
Occurrence flag of I/F
initialization
abnormality between
LED and LGC (CE81)
0
0-15
M
0 bit: Y
1st bit: M
2nd bit: C
3rd bit: K
0: Normal 1: Abnormality
1
08
Setting
mode
Process
Developm
ent
Toner near empty
5155
Toner near empty
threshold setting
1
0-5
M
0: The period from the appearance of the toner near-
empty sign to the actual complete consumption of the
toner is set to long.
1: Normal (Default)
2: The period from the appearance of the toner near-
empty sign to the actual complete consumption of the
toner is set to short.
4: Toner near-empty status threshold value: (%)*
5: Toner near-empty status threshold value: (Number of
sheets)*
* The toner near-empty status is displayed if the
remaining amount of toner is equal to or less than the
amount set in 08-5810/5811 (percentage or number of
sheets).
1
Yes
08
Setting
mode
Process
Developm
ent
Toner near empty
Fine adjustment of
threshold for
displaying remaining
toner and toner near
empty
5156
0
Y
100
50-150
M
Adjusts the threshold value for displaying remaining
amount of toner and toner near empty.
Display threshold value = default threshold value x
setting value/100 (unit: %)
4
08
Setting
mode
Process
Developm
ent
Toner near empty
Fine adjustment of
threshold for
displaying remaining
toner and toner near
empty
5156
1
M
100
50-150
M
Adjusts the threshold value for displaying remaining
amount of toner and toner near empty.
Display threshold value = default threshold value x
setting value/100 (unit: %)
4
08
Setting
mode
Process
Developm
ent
Toner near empty
Fine adjustment of
threshold for
displaying remaining
toner and toner near
empty
5156
2
C
100
50-150
M
Adjusts the threshold value for displaying remaining
amount of toner and toner near empty.
Display threshold value = default threshold value x
setting value/100 (unit: %)
4
72
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...