05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
05
Adjustmen
t mode
Process
Transfer
2761
Temperature/humidity
sensor temperature
display
23
0-100
M
Displays the temperature value set at the image quality
open-loop control transfer correction.
2
05
Adjustmen
t mode
Process
Transfer
2762
Temperature/humidity
sensor humidity
display
50
0-100
M
Displays the humidity value set at the image quality
open-loop control transfer correction.
2
05
Adjustmen
t mode
Process
Charger
2763
Drum thermistor
temperature display 1
23
0-100
M
(Unit: ºC)
2
05
Adjustmen
t mode
Process
Charger
2764
Drum thermistor
temperature display 2
23
0-100
M
(Unit: ºC)
2
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
0
Y normal speed
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
1
M normal speed
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
2
C normal speed
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
3
K normal speed
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
5
BK Normal speed
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
05
Adjustmen
t mode
Process
Transfer
1st transfer output
offset
2905
6
Y decelerating
5
0-10
M
Sets the offset amount of the 1st transfer output.
Offsetting level
0: 0.75 1: 0.80 2: 0.85 3: 0.90 4: 0.95 5: 1.00 6: 1.05
7: 1.10 8: 1.15 9: 1.20 10: 1.25
4
6
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...