e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 290
8.5.8
Blurred image
Fig.8-12
Cause/Section
Step
Check item
Measures
Scanner
1
Is the scanner bedewed?
Clean it.
Drum
2
Is the drum bedewed or dirty?
Wipe the drum with dry cloth.
*
Be sure never use alcohol or
other organic solvents because
they have bad effect on the drum.
Ozone
exhaust
3
Is the ozone exhaust fan operating
properly?
Check the connection of the
connector.
4
Is the ozone filter stained or
damaged?
Replace it.
LED head
5
Is there foreign matter or dust on the
LED head?
Clean the LED head.
Main charger
6
Is the charger grid dirty or deformed? Clean or replace the charger grid.
Main charger
7
Is there foreign matter on the
charger grid?
Remove foreign matter.
Clean or replace the charger grid.
Feeding direction
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...