e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 322
Cause/Section
Step
Check item
Measures
Image
adjustment/
setting
1
Is the margin adjustment of image
correct?
Adjust the margin.
2
Is the margin adjustment of image
correct when the paper size is not
selected in bypass feeding?
Adjust the margin.
3
Is the margin adjustment of image at
duplexing correct?
Adjust the margin. (05-4064)
4
Is the image location in primary/
secondary scanning direction
correct?
Adjust the location.
5
Is the reproduction ratio of image in
primary/secondary scanning
direction correct?
Adjust the reproduction ratio.
6
Is the tab setting correct?
Correct the setting.
Paper feeding
/Transport
area
7
Does the size of paper in the drawer
or LCF correspond to the setting?
Use the appropriate paper size or
correct the size setting.
8
Is the width between the slides in the
drawer correct (too wide)?
Correct the position of the slides.
9
Is the width between the slides of the
bypass tray correct (too wide)?
Correct the width.
10
Is the paper aligning amount
sufficient?
Adjust the aligning amount.
11
Are the feed roller and transport
roller dirty or worn out?
Clean or replace the rollers.
12
Does the paper mode correspond to
the paper type?
Use the appropriate paper type or
paper mode.
13
Using the recommended paper?
Use the recommended paper.
Transfer unit
14
Is there any stain caused by a poor
cleaning, etc. on the transfer belt?
Clean the transfer belt.
15
Is the transfer belt cleaning blade in
proper contact with the transfer belt?
Take off the transfer belt and check if
the transfer belt cleaning blade
pressure spring and the pressure
hook are installed properly.
16
Is the 2nd transfer roller rotating
properly?
Clean the area around the roller.
Otherwise replace the roller.
17
Is there any foreign matter or stain
on the 2nd transfer roller?
Clean or replace the roller.
18
Has the 2nd transfer roller reached
to its PM life?
Replace the 2nd transfer roller.
Fuser unit
19
Are the fuser belt and pressure roller
dirty?
Clean the fuser belt and pressure
roller.
20
Is the separation finger dirty?
Clean the separation finger.
21
Is the rib of transport guide dirty?
Clean the rib.
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...