05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
05
Adjustmen
t mode
Process
Developm
ent
Adjustment of auto-
toner initial
adjustment reference
setting value (YMCK)
2405
2
Adjustment of
(YMCK) C
Refer to
content
s
0-255
M
<Default value>
25/30/35ppm: 130
45/50ppm: 140
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Adjustment of auto-
toner initial
adjustment reference
setting value (YMCK)
2405
3
Adjustment of
(YMCK) K
Refer to
content
s
0-255
M
<Default value>
25/30/35ppm: 130
45/50ppm: 140
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Initialization of auto-
toner
2406
Automatic adjustment
(Y, M, C)
-
0-255
M
The value starts changing approx. 3 minutes after this
adjustment is started. The value is automatically set
during this adjustment (approx. 2 minutes).
(As the value increases, the sensor output increases
correspondingly.)
5
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
Y
2627
0
Lower limit
200
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
Y
2627
1
Upper limit
900
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
M
2628
0
Lower limit
200
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
M
2628
1
Upper limit
900
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
C
2629
0
Lower limit
200
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
C
2629
1
Upper limit
900
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
K
2630
0
Lower limit
200
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Developm
ent
Developer bias DC(-)
calibration voltage
K
2630
1
Upper limit
900
0-1000
M
(Unit: V)
4
Yes
05
Adjustmen
t mode
Process
Image
control
Target value of 1st
pattern (high density
control)
2662
0
Y
295
100-450
M
Sets the target value of 1st pattern (high density)
control for image control.
4
2
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...