BACKUP FUNCTION
12 - 4
[C] Confirmation of the error
"Backup Failed" or “Restore Failed” is displayed on the lower left part of the LCD screen when the data
have not been properly backed up or restored.
Moreover, details of an error are displayed under the above message.
(The following is an example screen when "USB device not detected" is displayed.)
Fig.12-3
In this case, turn the power OFF and then check the following items. After confirming and solving the
problem, back up / restore the data again from the beginning.
•
Does the USB device meet the conditions being used for this cloning?
•
Is the updated program file written on the USB device properly?
•
Is the USB device installed properly?
•
Is the USB device or the equipment damaged?
Backup
Display content
Error content
USB device not detected
The USB device has not been installed.
SRAM Device Not Connected
The SRAM board (for the SYS board) has not been
installed.
Backup not created
Creation of the Backup file of data of the SRAM board
(for the SYS board) has been failed.
Encryption Failed
An encryption of the backup file has been failed.
password Not Appended to Backup
Addition of the encryption password has been failed.
MFP Serial Number Not Set
Acquisition of the MFP Serial No. has been failed.
Restore
Display content
Error content
USB device not detected
The USB device has not been installed.
SRAM Device Not Connected
The SRAM board (for the SYS board) has not been
installed.
Invalid Backup File
The SYS board has not been recognized.
No Backup File Exists
Backup file has not existed in the USB device.
Invalid password
An incorrect password has been entered.
Decryption Failed
Decoding of the backup file has been failed.
SRAM Data Cloning Mode
Firmware Version : x. x. x. x
Select number (1-2) and press START key
Backup Failed
USB device not detected
Update Mode : 59 Mode
2: Restore SRAM Data from USB
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...