05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Fuser
Lower limit value of
control temperature
Plain paper/Low
temperature
2206
2
Color/Heat roller
(Center)
13
0-18
M
0: 80
℃
1: 85
℃
2: 90
℃
3: 95
℃
4: 100
℃
5: 105
℃
6:
110
℃
7: 115
℃
8: 120
℃
9: 125
℃
10: 130
℃
11:
135
℃
12: 140
℃
13: 145
℃
14: 150
℃
15: 155
℃
16:
160
℃
17: 165
℃
18: 170
℃
4
08
Setting
mode
Process
Fuser
Lower limit value of
control temperature
Thick paper 1
2208
0
Heat roller (Center)
Refer to
contents
0-18
M
0: 80
℃
1: 85
℃
2: 90
℃
3: 95
℃
4: 100
℃
5: 105
℃
6:
110
℃
7: 115
℃
8: 120
℃
9: 125
℃
10: 130
℃
11:
135
℃
12: 140
℃
13: 145
℃
14: 150
℃
15: 155
℃
16:
160
℃
17: 165
℃
18: 170
℃
<Default value>
25/30/35ppm: 13
45/50ppm: 12
4
08
Setting
mode
Process
Fuser
Lower limit value of
control temperature
Thick paper 2
2209
0
Heat roller (Center)
13
0-18
M
0: 80
℃
1: 85
℃
2: 90
℃
3: 95
℃
4: 100
℃
5: 105
℃
6:
110
℃
7: 115
℃
8: 120
℃
9: 125
℃
10: 130
℃
11:
135
℃
12: 140
℃
13: 145
℃
14: 150
℃
15: 155
℃
16:
160
℃
17: 165
℃
18: 170
℃
4
08
Setting
mode
Process
Fuser
Lower limit value of
control temperature
Thick paper 3
2210
14
0-18
M
0: 80
℃
1: 85
℃
2: 90
℃
3: 95
℃
4: 100
℃
5: 105
℃
6:
110
℃
7: 115
℃
8: 120
℃
9: 125
℃
10: 130
℃
11:
135
℃
12: 140
℃
13: 145
℃
14: 150
℃
15: 155
℃
16:
160
℃
17: 165
℃
18: 170
℃
1
08
Setting
mode
Process
Fuser
Temperature setting
for starting
abnormality handling
2233
Envelope (Center/side
thermistor)
6
0-12
M
0: 120
℃
1: 125
℃
2: 130
℃
3: 135
℃
4: 140
℃
5:
145
℃
6: 150
℃
7: 155
℃
8: 160
℃
9: 165
℃
10:
170
℃
11: 175
℃
12: Disabled
1
08
Setting
mode
Process
Fuser
Switchover of print
speed
2245
Thick paper 3
0
0-2
M
0: Disabled
1: Enabled for 5 minutes after warm-up
2: Enabled
1
08
Setting
mode
Process
Fuser
Temperature setting
for starting
abnormality handling
Special paper
(Center/side
thermistor)
2246
0
Special paper 1
4
0-12
M
0: 120
℃
1: 125
℃
2: 130
℃
3: 135
℃
4: 140
℃
5:
145
℃
6: 150
℃
7: 155
℃
8: 160
℃
9: 165
℃
10:
170
℃
11: 175
℃
12: Disabled
4
08
Setting
mode
Process
Fuser
Temperature setting
for starting
abnormality handling
Special paper
(Center/side
thermistor)
2246
1
Special paper 2
4
0-12
M
0: 120
℃
1: 125
℃
2: 130
℃
3: 135
℃
4: 140
℃
5:
145
℃
6: 150
℃
7: 155
℃
8: 160
℃
9: 165
℃
10:
170
℃
11: 175
℃
12: Disabled
4
13
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...