05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Image
control
Image quality
Image quality closed-
loop control automatic
start-up
2509
Setting of
accumulated print
volume
1000
100-9999
M
Sets the number of accumulated print volume to
perform closed-loop control when "1" (valid) is set in 08-
2498.
Image problems may occur if the value extremely
smaller than the default value is set to the equipment
whose print ratio of monochrome is relatively high.
(unit: pages)
1
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Normal speed
2513
0
Y
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Normal speed
2513
1
M
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Normal speed
2513
2
C
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Normal speed
2513
3
K
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Decelerating
2514
0
Y
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Decelerating
2514
1
M
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Decelerating
2514
2
C
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
mode
Process
Image
control
Contrast voltage
offset correction
setting
Decelerating
2514
3
K
5
0-10
M
0: -100 1: -80 2: -60 3: -40 4: -20 5: 0 6: +20 7: +40
8: +60 9: +80 10: +100
(Unit: V)
4
08
Setting
Mode
Process
Image
control
Abnormality detection Display/0 clearing
2528
Y
0
0-16
M
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
1
Yes
08
Setting
Mode
Process
Image
control
Abnormality detection Display/0 clearing
2529
M
0
0-16
M
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
1
Yes
18
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...