[CB50] Staple motor (M10) abnormality
MJ-1036
[CB50] Stapler home position error
*
You receive a [CB50] error when the [EA50] error occurs three times in succession.
Front alignment motor (M5)
Check the connectors and harnesses between the front alignment
motor (M5) and the finisher control PC board (CN10).
Parts to be replaced
Remark
Front alignment motor (M5)
Finisher controller PC board
Error
Timing of detection
Stapler motor (M10)
Staple unit clinching home position
sensor (S16)
The staple unit clinching home position sensor (S16) does not
detect the opening of the staple unit after the stapler motor
(M10) has been driven reversely in the specified time from the
closing during the initial movement of the staple unit.
The staple unit clinching home position sensor (S16) does not
detect the opening of the staple unit in the specified time from
the closing during the clinching movement of the staple unit,
and also this sensor does not detect the opening by the reverse
rotation of the motor after the stapler is stopped.
The staple unit clinching home position sensor (S16) does not
detect the closing of the staple unit after the specified time
during the clinching movement of the staple unit.
The staple unit clinching home position sensor (S16) does not
detect the opening of the staple unit at the start of the clinching.
Probable cause
Checking and measures
Staple motor (M10) abnormality
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the staple unit.
Staple unit clinching home position
sensor (S16) abnormality
Measure the voltage on CN16 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when the sensor is ON and within the range of 3.3V
±
5% when OFF. If the voltage does not fall within the range
mentioned, replace the staple unit.
Staple unit improper clinching
prevention sensor (S15)
abnormality
Measure the voltage on TP25 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when not shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connectors. (Finisher control PC board (FIN): CN16, CN17)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensors, switch
and connectors, exchange the finisher control PC board (FIN).
Check item
Measures
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...