SETTING / ADJUSTMENT
6 - 85
Notes:
Flip up protection sheet[1] for the doctor
blade from the sleeve before inserting the
gauge. Also, be sure not to damage the
protection sheet[1].
Fig.6-33
(4)
Insert the gauge "0.55" of the doctor-sleeve
gap jig[1] between the developer sleeve and
the doctor blade to make sure that the gauge
can move smoothly in the front/rear direction
and the gauge "0.65" cannot be inserted into
the gap.
Fig.6-34