REMOTE SERVICE
10 - 28
Fig.10-30
Key in the time (acceptable values: 00:00-23:59) in “Time”.
Key in the time in the hour column of “Time”, press the scroll button, key in the time in the minute
column of “Time”.
After all the settings are completed, press the [OK] button. The display returns to the screen in
step (5).
(7)
Press the [OK] button. The setting completes.
Notes:
Service Notification setting is also available from the following setting mode (08).
Items
08 code
Contents
Service Notification setting
9793
0: OFF (Invalid) 1:E-mail 2:FAX
E-mail address 1
9794
Maximum 192 letters
E-mail address 2
9607
Maximum 192 letters
E-mail address 3
9608
Maximum 192 letters
FAX number
9784
Maximum 32 digits
Total Counter Transmit setting
9795
0: OFF (Invalid) 1: ON (Valid)
Total counter transmission date
setting
9796
0 to 31
Total counter transmission date
setting(2)
9880
0 to 31
Day of total counter data
transmission
9881
1 byte
00000000(0)-01111111(127)
From the 2nd bit - Sunday, Monday,
Tuesday, Wednesday, Thursday, Friday,
Saturday
Total counter transmission interval
setting
(Hour/Hour/Minute/Minute)
9606
00:00-23:59
Service Call Transmit setting
9605
0: OFF (Invalid) 1: ON (Valid)
PM Counter Transmit setting
9797
0: OFF (Invalid) 1: ON (Valid)
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...