ERROR CODE AND TROUBLESHOOTING
8 - 319
8.5.26
Uneven light distribution
Fig.8-31
Cause/Section
Step
Check item
Measures
Original glass
1
Is the original glass dirty?
Clean the glass.
Main charger
2
Are the needle electrode, grid and
case dirty?
Clean or replace them.
Discharge
LED
3
Is the discharge LED dirty?
Clean it.
Scanner
exposure
lamp
4
Are the reflector, exposure lamp,
mirrors, lens, etc. dirty?
Clean them.
5
Is the exposure lamp tilted?
Adjust the installed position of the
lamp.
6
Is the lamp discolored or degraded?
Replace it.
Feeding direction
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...