General-Purpose Mode
1254
SPRUHE8E – October 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
External Peripheral Interface (EPI)
states are read back. With the EPI controller, the non-blocking interface may also be used to perform
reads based on a fixed time rule via the EPIBAUD clock rate.
shows how the EPI0S[31:0] signals function while in General-Purpose mode. Notice that the
address connections vary depending on the data-width restrictions of the external peripheral.