3-1-4. L Cassette Position and S Cassette Position
1. L Cassette Position
L cassette position means that the reel tables are in the position of L cassette tape.
There are two methods of putting the reel tables into the L cassette position from the
S cassette position with the cassette compartment taken off the unit.
Method
1
: With the power turned on, press into the L cassette REC INHIBIT
sensor about three seconds.
Method
2
: 1. Remove the SE-606 board. (Refer to Section 3-14.)
2. Turn fully the gear of reel shift motor in the arrow C direction.
3-1. General Information for Parts Replacement
L Cassette Position
C
S reel table
T reel table
Gear
L cassette
REC INHIBIT sensor