![Sony GY-8240FC Скачать руководство пользователя страница 208](http://html.mh-extra.com/html/sony/gy-8240fc/gy-8240fc_maintenance-manual_420972208.webp)
4-28
GY-8240UWD
GY-8240FC
A
EF
1
2
3
4
TP608
*
Oscilloscope
CH-1 : TP608/CT-205 board (TC ANA signal)
<CT-205 board, side A>
4-8. Time Code Level Adjustment in Rev Mode
Equipment
.
Oscilloscope
Tool
.
Alignment tape YR2-1A:
8-960-074-32
Preparation
1. Turn the Power Off
2. Connect the Oscilloscope
CH-1: TP608/CT-205 board (TC ANA signal)
3. Set the Alignment Tape
Set the YR2-1A and put a weight (about 1000 g)
on the cassette so that it does not rise up.
4-8. Time Code Level Adjustment in Rev Mode
Preparation
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...