5-4. DIAG Mode
o. AD-Adjust Data Display
Function:
Displays SV adjustment values.
n
The SV adjustment values displayed cannot be changed.
Operation:
(1) Enter “AD
"
”. The following is displayed.
CapstanA: Capstan FG A phase
CapstanB:
Capstan FG B phase
SReelA:
S reel motor FG A phase
SReelB:
S reel motor FG B phase
TReelA:
T reel motor FG A phase
TReelB:
T reel motor FG B phase
Thread:
Fixed value
STension:
S tension sensor
TTension:
T tension sensor
CapOffst:
Capstan offset (Fixed value)
CapQpl:
For capstan IC
NoConne:
Not used
PgCoarse:
PG rough adjustment value
PgFine:
PG fine adjustment value
NotUsed0: Not used
NotUsed1: Not used
Padding:
Not used
CheckSum: SV adjustment value checksum
n
The Value marked with “
*
” is fixed or not used.
**Adjust Data in Flash, not in RAM..
CapstanA=80
CapstanB=85
SReelA =80
SReelB =85
TReelA =7D
TReelB =7B
Thread =0C*
STension=7F
TTension=5E
CapOffst=80*
CapQpl =92
NoConne=80*
PgCoarse=14
PgFine =FE
NotUsed0=0000*
NotUsed1=0000*
Padding =00*
CheckSum=70
(*)Used as Constant or Not Used.
SV1_DIAG=>
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...