SV1_DIAG=>R2
"
[InL-][InR-][LSize-][Exist*][Vert*][UdEnd*]
0000 0000 0000
5-4. DIAG Mode
d. R2-Cassette Compartment Switch Check
Function:
Displays the state of the sensor (switch) of the cassette compartment.
Refer to the next page on the position of each sensor (switch).
Operation:
(1) Without loading any cassette, enter “R2
"
”. The following will be displayed.
The following indicates the current status of the respective sensors. When the sensor is functioning, the
display changes from “
_
” to “
*
”.
[InL-]:
Cassette-in L sensor
[InR-]:
Cassette-in R sensor
[LSize]:
Cassette Size sensor
[Exist-]:
Cassette Exist
[Vert-]:
Cassette down (2) sensor
[UdEnd-]:
Cassette down (1) sensor
(2) Check the following.
1
When the Cassette-in L sensor is pressed, the display changes from “[InL-]” to “[InL
*
]”.
2
When the Cassette-in R sensor is pressed, the display changes from “[InR-]” to “[InR
*
]”.
3
When the Cassette Size sensor is pressed, the display changes from “[LSize-]” to “[LSize
*
]”.
(3) To end, enter “ : ”.
If the above fails:
.
Check the corresponding sensor on the PC-70 board.
.
Check the sensor input port of the CPU on the SV-205 board.
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...