![Sony GY-8240FC Скачать руководство пользователя страница 164](http://html.mh-extra.com/html/sony/gy-8240fc/gy-8240fc_maintenance-manual_420972164.webp)
3-78
GY-8240UWD
GY-8240FC
3-23. T Drawer Assembly Replacement and Adjustment
3-23-1. T Drawer Assembly Replacement
Outline
Replacement
1.
Removing the ME Wire
2.
Removing the T Drawer Assembly
3.
Installing the T Drawer Assembly
4.
Installing the ME Wire
5.
Confirming the ME Wire Operation
6.
Confirming the T Drawer Assembly Operation
Adjustment after Replacement
7.
Adjusting the Slant Guide Slantness (Refer to Section 3-23-2.)
Note
Prepare a new stop washer when replacing the T drawer assembly.
.
Stop washer (d = 2.3 mm): 3-669-596-00
Tools
.
Cleaning cloth:
3-184-527-01
.
Cleaning fluid:
9-919-573-01
.
Slide calipers (or an equivalent)
Preparation
1.
Set the unit into the unthreading end mode. (Refer to step 2 in Section 3-1-3.)
2.
Turn the power off and remove the power cord.
3.
Remove the top panel. (Refer to Section 1-1.)
4.
Remove the plate MD. (Refer to Section 1-2.)
5.
Remove the cassette compartment. (Refer to Section 1-2.)
3-23. T Drawer Assembly Replacement and Adjustment
3-23-1. T Drawer Assembly Replacement
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...