5-121
GY-8240UWD
GY-8240FC
5-10-3. Setup Information Set
Function:
Sets the setup data.
Operation:
Enter “1
"
”.
The screen will prompt for the setting value. Enter a setting value for each item, and press
"
.
Pressing only
"
does not change the current value.
(The current value is displayed in the [ ].)
At the end, a message to confirm whether to set the value entered will be displayed. Entering “y
"
” sets
the values. Entering “n
"
” cancels the setting.
For GY-8240UWD
Setup Information Set Execution Screen
1. SCSI ID
Function:
Sets the SCSI ID.
Setting:
Value between 0 and 15 is acceptable.
2. IP address
Function:
Sets the ID address.
Setting:
The area is divided into four blocks. Value between 0 and 255 is acceptable for each of the
four blocks.
Enter “.” between each block.
3. Subnet mask
Function:
Sets the subnet mask.
Setting:
The area is divided into four blocks. Value between 0 and 255 is acceptable for each of the
four blocks.
Enter “.” between each block.
4. Gateway address
Function:
Sets the gateway address.
Setting:
The area is divided into four blocks. Value between 0 and 255 is acceptable for each of the
four blocks.
Enter “.” between each block.
SETUP=> 1
"
*****[ SETUP INFORMATION SET ]*************************
SCSI ID (0-15) [5] => 5
IP address (0-255 each) [127. 0. 0. 1] => 127.0.0.1
Subnet mask (0-255 each) [255.255.255. 0] => 255.255.255.0
Gateway address (0-255 each) [ 0. 0. 0. 0] => 0.0.0.0
Unload mode (0:NORMAL/1:FAST) [1] => 1
Auto load mode (0:OFF/1:ON) [1] => 1
Fast unload location (0:NORMAL/1:TOP) [0] => 0
Auto format mode (0:OFF/1:ON) [0] => 1
On the halfway (0:OFF/1:ON) [0] => 0
Compression mode (0:SCSI/1:ON/2:OFF) [0] => 1
File mark flush mode(0:OFF/1:ON) [0] => 0
Recover TYPE (0-2) [1] => 1
Fast read mode (0:OFF/1:ON) [1] => 0
Are you sure?(Y:yes/N:no)=> y
5-10. SETUP Mode
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...