![Sony GY-8240FC Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/sony/gy-8240fc/gy-8240fc_maintenance-manual_420972078.webp)
2-2
GY-8240UWD
GY-8240FC
3. Accuracy of hours meter
This unit does not use a battery backup CPU nor any special device for storing the hours meter data.
The hours meter data stored contains a small amount of allowable error.
This unit automatically stores hours meter data in the flash memory so that the storage interval becomes geometric reality.
The nth storage later from the power ON state is performed 1.5
n
_
1
minutes from the previous storage.
The maximum interval is 24 hours. The data will be saved in the memory after extrapolation arithmetic of half of the next
storage interval.
The error of the hours meter data stored is about
±
20% (maximum) when n is large.
The cleaning and thread counter are not stored in the hours meter everytime the counter is increased, but is updated at the
above storage interval.
2-1-2. Periodic Check List
Perform periodic check in accordance with the table.
The replacement time shown in the table is not the guarantee term of parts.
Note:
The part marked with “
↓
” in the table is replaced simultaneously with when the part in the column below
its mark is replaced.
The “R” mark in this table indicates the replacement timing of parts.
Item
Hours
Inspetion Hours (h)
Replacement Parts
Procedure
Meter
*
*
*
*
*
1
5000
10000
Part Name
Parts No.
Q’ty
Drum Block
Upper Drum
*
2
2
R
↓
UPPER DRUM ASSY (DDR-58-R)
A-8324-483-A
1
Refer to Section 3-2.
Brush/Slip Ring
2
R
↓
BRUSH SR4 ASSY (RP)
A-8312-151-
1
Refer to Section 3-4.
Drum
*
2
2
–
R
DRUM ASSY (DDH-58A-R)
A-8324-482-A
1
Refer to Section 3-3.
Cleaners
Cleaning Roller
*3
4
Replace when used
↓
CLEANER ASSY (RP)
A-8279-790-A
1
Refer to Section 3-5.
30,000 times.
Rotary Head Cleaner
2
–
R
W CLEANER ASSY (RP)
A-8279-791-A
1
Refer to Section 3-5.
CTL/TC Head Cleaner
*
3
2
Replace when used 1,000H.
CL ARM ASSY
X-3605-789-
1
Refer to Section 3-6.
Tape Running System
Pinch Roller
*
3
2
R
R
PINCH ARM ASSY
X-3605-881-
1
Refer to Section 3-9.
CTL/TC Head
2
–
R
AT HEAD ASSY
A-8267-422-
1
Refer to Section 3-8.
Capstan Motor
2
R
R
SCV16/J-RP
A-8325-190-A
1
Refer to Section 3-11.
Driving System
Pinch Solenoid
2
–
R
PINCH PRESS ASSY
A-8324-938-
1
Refer to Section 3-10.
Reel Motor
2
–
R
REEL MOTOR TABLE (T) ASSY (RP) A-8326-890-A
1
Refer to Section 3-14.
REEL MOTOR TABLE (S) ASSY (RP) A-8326-889-A
1
Others
Fan Motor (Power supply)
1
Replace when used 40,000H.
DC FAN
9-885-001-66
1
Refer to Section 1-8-2.
Fan Motor (Rear panel)
1
Replace when used 50,000H.
DC FAN
1-698-779-
1
Refer to Section 3-25.
*
1: Refer to Section 2-1-1.
*
2: Do not subject this unit to high humidity or excessive dust. This may shorten the life of these parts. Therefore, it is recommended to
use this unit in an air-conditioned and dust-free environment and store the cassette at ordinary temperature and humidity.
*
3 : The life of these parts may be shortened depending on the operating condition of this unit or the operating environment.
2-1. Periodic Check
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...