5-13. Troubleshooting
5-13-7. List of Self-Diagnosis Results Codes and Countermeasures
When error code 1D1C3XAA (X
≠
D) that is not listed below occurs, refer to “Countermeasures for SV Error Code” in
Section 5-13-6.
Error Code
Details
Remedy
00044080
Bank memory check error
Replace FM-75 board.
00044081
FM-CPU RAM check error
00044085
FM-CPU ROM check error
00044086
Check error
00044087
FM-CPU DMA check error
1D1C10C0
EE-2 error
Replace DPR-160 board.
1D1C10C1
EE-3 error
Replace DPR-160 board, FM-75 board.
1D1C10C2
EE-2 error (With CRC)
Replace DPR-160 board.
1D1C10C3
EE-3 error (With CRC)
Replace DPR-160 board, FM-75 board.
1D1C207B
DIAG executed in Tape-IN state.
Eject cassette and execute again.
1D1C3D21
S reel FG duty check results were unsatisfactory.
Check or replace S reel motor, SV-205 board, S reel
brake.
1D1C3D22
S reel PG for S reel FG teeth number diagnosis not output.
Check or replace S reel motor, SV-205 board.
1D1C3D23
S reel FG teeth number was abnormal.
1D1C3D28
Unexpected state occurred such as cassette was loaded during
Execute again.
S reel diagnosis.
1D1C3D31
T reel FG duty check results were unsatisfactory.
Check or replace T reel motor, SV-205 board, T reel
brake.
1D1C3D32
T reel PG for T reel FG teeth number diagnosis not output.
Check or replace T reel motor, SV-205 board.
1D1C3D33
T reel FG teeth number was abnormal.
1D1C3D38
Unexpected state occurred such as cassette was loaded during
Execute again.
T reel diagnosis.
1D1C3D41
Capstan FG check results were unsatisfactory.
Check or replace capstan motor, SV-205 board.
1D1C3D48
Unexpected state occurred such as cassette was loaded during
Execute again.
capstan FG check.
1D1C3D51
S tension check results were unsatisfactory.
Check or replace SV-205 board. (Note: S tension
sensor is not related.)
1D1C3D58
Unexpected state occurred such as cassette was loaded during
Execute again.
S tension check.
1D1C3D61
T tension check results were unsatisfactory.
Check T tension sensor, SV-205 board.
1D1C3D68
Unexpected state occurred such as cassette was loaded during
Execute again.
T tension check.
1D1C3D71
Failed in PG automatic adjustment.
Check cassette type.
Re-execute no-cassette servo adjustment
Check or replace DPR-160 board and SV-250 board.
Or replace drum.
1D1C3D72
Could not detect signal required for PG automatic adjustment.
Check cassette type.
1D1C3D73
PG automatic adjustment ended in timeout.
Check or replace DPR-160 board and SV-250 board.
Or replace drum.
1D1C3D78
PG automatic adjustment was not possible.
Execute again.
1D1C3D81
S reel motor terminal voltage check results were unsatisfactory.
Check or replace S reel motor, SV-205 board.
1D1C3D88
Unexpected state occurred such as cassette was loaded during
Execute again.
S reel motor terminal voltage check.
Continued to next page
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...