Error Code
Details
Remedy
1x3C
Could not read ID during READ (forward).
Unload and clean CTL/TC head.
Clean tape path.
.
Replace cassette.
.
Replace CT-205 board.
.
Replace harness.
1x40
Parity error of W(2)/R(2)
*
2
Hardware error
1x41
Parity error of W(3)
*
2
Replace FM-75 board.
1x42
Parity error of W(4)
*
2
Hardware error
Replace FM-75 board or DPR-160 board.
1x43
Parity error of W(5)
*
2
Hardware error
Replace DPR-160 board.
1x44
Parity error of W(6)/R(1)
*
2
Hardware error
Replace FM-75 board or DPR-160 board.
1x45
Correction error of EDC of W(1)
*
2
Hardware error
Replace FM-75 board.
1x46
Fatal error of EDC of W(1)
*
2
Hardware error
1x47
Framing error of W(3)
*
2
Replace FM-75 board.
1x48
Framing error of R(1)
*
2
1x49
Framing error of R(2)
*
2
1x4A
CRC error of W(6)/R(1)
*
2
1x4F
System fell in unoperatable state.
1x5B
Cassette was REC-inhibited. Or attempted to write in DTF-1.
Replace FM-75 board.
1x6B
There are errors in packet of command block.
Software error
1x6C
Requested unsupported command.
Replace FM-75 board.
1x6D
Command sequence error
1x6F
Command request in ABORT mode
1x7B
Set in EOT during operating.
Eject and replace cassette.
.
Replace tape end sensor.
.
Replace sensor harness.
.
Replace SV-205 board.
1x7F
Timed-out without changing TTP status.
Eject and replace cassette.
1090
SYS command ACK waiting time-out
Software error
1091
SYS command FREE waiting time-out
Replace FM-75 board.
1092
FMT command INT waiting time-out 1
1093
FMT command INT waiting time-out 2
1094
FMT command INT waiting time-out 3
1095
FMT command INT waiting time-out 4
1xA0
Uncorrected error in Ach/Ech
.
Clean with cleaning cassette.
1xA1
Uncorrected error in Ach only
.
Head cleaning
1xA2
Uncorrected error in Ech only
(Refer to “2-2-4. Stationary Heads
Cleaning”.)
.
Replace cassette.
.
Replace DPR-160 board.
.
Replace drum.
1xA3
Received command after C2 over.
Software error
1xA4
Received command after IN over.
Replace FM-75 board.
Continued to next page
5-13. Troubleshooting
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...