3-21
GY-8240UWD
GY-8240FC
Contacting point
(Wipe with a dry
cleaning cloth)
.
Brush slip ring assembly
.
DR-346 board
Contacting point
(Wipe with a dry
cleaning cloth)
Contacting point
(Wipe with a dry
cleaning cloth)
Contacting point
(Wipe with a dry
cleaning cloth)
PSW2
x
16
CN2
HN-258 board
Brush slip ring assembly
Removal
1. Disconnecting the Flexible Card Wire
Disconnect the flexible card wire from connector
CN2 on the HN-258 board.
2. Removing the Brush Slip Ring
Assembly
(1) Remove the two screws, then remove the
brush slip ring assembly.
n
Do not apply excessive force to the brush slip
ring assembly at that time.
(2) Turn the brush slip ring assembly upside
down, and take out the two screws.
n
Use care not to fall the screws into the cover.
Installation
3. Cleaning
Wipe the brush slip ring assembly mounting
surface (shaded portion in the figure) and the DR-
341 board contacting points with a dry cleaning
cloth.
n
Do not apply cleaning fluid to the contacting
points.
3-4. Brush Slip Ring Assembly Replacement
Remove the Brush/Slip Ring Assembly
Cleaning
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...