5-181
GY-8240UWD
GY-8240FC
5.
Turn the power on, and set the unit to the line mode. (Refer to Section 1-11.)
n
Do not load a cassette at this time.
6.
Run the terminal emulator software.
7.
Enter “diag
"
” from the start-up screen to enter the DIAGNOSTIC mode.
8.
Next, enter “15
"
” to display the DSP DIAGNOSTIC menu.
9.
Next, enter “26
"
” and turn the power of the CCM-33 board on.
10. Adjust CT1 of the CCM-33 board using the adjustment screwdriver to satisfy the following specifica-
tion.
Adjustment point: CT1/CCM-33 board
Specification:
Amplitude A = Sine waveform, maximum (more than 11 V p-p)
n
As the amplitude of the waveform is easily affected by the probe, twist two probe cables together to
measure.
11. After the adjustment, set the power of the unit off, and remove the probe.
Checking Method
12. Turn the power of the unit on.
13. Load and unload a formatted tape, and check that no errors occur.
14. After checking, attach the front panel.
5-16. Telefile Adjustment
A
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...