![Sony GY-8240FC Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/sony/gy-8240fc/gy-8240fc_maintenance-manual_420972077.webp)
2-1
GY-8240UWD
GY-8240FC
2-1. Periodic Check
To make the most of the functions, fully realize performance of the unit, lengthen the life of the unit and
tape, a periodic check is recommended.
Write value of “Hours Meter” (the value which would not be reset) into the Service Record Label at-
tached to the back of top panel at service of periodic maintenance.
And make reference to this service record for decision on the timing of next check.
2-1-1. Hours Meter
The hours meter can be displayed on the terminal screen of a personal computer (PC) connected to
RS-232C port of this unit. Perform a periodic check with this hours meter as a reference.
1. Display procedure
1.
After entering “DIAG” from the PC connected to this unit, start the Self Diagnosis mode by pressing
the enter key.
“DIAG =>” is displayed as a prompt.
2.
After entering “5” as a command, press the enter key.
The value of “Hours Meter” is displayed on the terminal display of the PC.
3.
When quitting the Self Diagnosis mode, enter “QUIT” on the PC and press the enter key.
2. Contents of display
HOURS METER
DESCRIPTION
1
Operation Hours
Accumulated operation hours
*
1
2
Drum Run Hours
Accumulated drum running hours
*
2
3
Thread Counter
Accumulated threading/unthreading times
*
3
_
Drum Run-1 Hours (res)
Accumulated drum running hours 1
*
2
(Make resetting after the drum replacement with Hours Meter Clear command.)
_
Drum Run-2 Hours (res)
Accumulated drum running hours 2
*
2
(It will be reset automatically by the use of the cleaning tape.)
_
Thread Counter-1 (res)
Accumulated threading/unthreading times
*
3
(It is possible to reset by the Hours Meter Clear command.)
_
Cleaning (times)
Accumulated rotary head cleaning operation times
4
Cleaning-1 (times)
Accumulated rotary head cleaning operation times
(Make resetting after the cleaner replacement with Hours Meter Clear command.)
*
1: Accumulated hours when the power of the unit is on.
*
2: Accumulated hours when the drum rotates in the threading end state.
*
3: A definition of threading operation is as follow:
Unthreading end state
→
Threading end state
→
Unthreading end state
→
...
Section 2
Periodic Maintenance and Inspection
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...